0600-0041-0000 Rev. F Made in the U.S.A.
April 2006 $15.00
User’s Manual
Registered Company
Winona, Minnesota USA
ISO 9001
ISO 9001
TOTAL
3 Year Warranty
CUS
CUS
T
T
O
O
M
M
ER
ER
S
S
A
A
TISF
TISF
A
A
CTI
CTI
O
O
N
N
Series SD
PID Controller and
PID Profiling Controller
1241 Bundy Boulevard., Winona, Minnesota USA 55987
Phone: +1 (507) 454-5300, Fax: +1 (507) 452-4507 http://www.watlow.com
Zobrazit stránku 0
1 2 3 4 5 6 ... 87 88

Shrnutí obsahu

Strany 1 - PID Profiling Controller

0600-0041-0000 Rev. F Made in the U.S.A.April 2006 $15.00User’s ManualRegistered CompanyWinona, Minnesota USAISO 9001ISO 9001TOTAL3 Year WarrantyCU

Strany 2 - Warranty

Watlow Series SD • 8 • Chapter 2 Install and Wire Installing the 1/8 DIN Series SD Controller1. Make the panel cutout using the mounting templat

Strany 3 - Table of Contents

Watlow Series SD • 9 • Chapter 2 Install and Wire Installing the 1/4 DIN Series SD Controller1. Make the panel cutout using the mounting templat

Strany 4 - Chapter 1: Overview

Watlow Series SD • 10 • Table of ContentsWatlow Series SD • 10 • Chapter 2 Install and Wire 1234568910 1112131412341213 148910115671234568910

Strany 5 - Features and Benefits

Watlow Series SD • 11 • Chapter 2 Install and Wire Wiring the Series SDThe model number for each output option appears with its wiring dia-gram. C

Strany 6 - Dimensions

Watlow Series SD • 12 • Chapter 2 Install and Wire Figure 12a — Thermocouple Input (all model numbers)Thermocouples are polarity sensitive. The n

Strany 7 - Panel Cutout

Watlow Series SD • 13 • Chapter 2 Install and Wire Figure 13a — 0 to 20 mA Process Input (all model numbers)• Input impedance 100 , dc only.• C

Strany 8 - Installation

Watlow Series SD • 14 • Chapter 2 Install and Wire Figure 14a — Output 1 Switched DCSD_ _ - _ C _ _ - _ _ _ _ • Supply current 30 mAÎ (dc) maximu

Strany 9

Watlow Series SD • 15 • Chapter 2 Install and Wire çWarning:Use National Electric (NEC) or other country-specific standard wiring and safety pract

Strany 10

Watlow Series SD • 16 • Chapter 2 Install and Wire Figure 16a — Output 3 Mechanical RelaySD_ _ - _ _ _ E - _ _ _ _ • Form A contact• 5 A, resisti

Strany 11

Watlow Series SD • 17 • Chapter 2 Install and Wire Figure 17a — Output 3 Open CollectorSD_ _ - _ _ _ C - _ _ _ _ • Maximum current sink 250 mAÎ (

Strany 12

Safety InformationWe use note, caution and warning symbols throughout this book to draw your attention to important operational and safety information

Strany 13 - Wiring the Series SD

Watlow Series SD • 18 • Table of ContentsWatlow Series SD • 18 • Chapter 2 Install and Wire When choosing an EIA/TIA 232 to 485 converter, loo

Strany 14 - 0 to 10VÎ (dc) Process Input

Watlow Series SD • 19 • Table of ContentsWatlow Series SD • 19 • Chapter 2 Install and Wire Ethernet Gateway The EM00-GATE-0000 is a bridge t

Strany 15 - Output 1 Mechanical Relay

Watlow Series SD • 20 • Chapter 3 Keys and DisplaysChapter 3: Keys and Displays34123%SDSD1/4 DIN123 %SDSDSDSD1/8 DIN HorizontalSDSD231SDSD%1/16

Strany 16 - Output 2 Mechanical Relay

Watlow Series SD • 21 • Chapter 3 Keys and DisplaysHome Page OverviewThe Home Page is the default display of the Series SD controller. The process

Strany 17 - Output 2 EIA/TIA-485

Watlow Series SD • 22 • Chapter 3 Keys and Displays Operations Page Overview The Operations Page contains parameters accessed during normal day-

Strany 18 - Output 3 Switched DC

Watlow Series SD • 23 • Chapter 3 Keys and DisplaysSetup Page (continued)[Ot`2] Output 2 Function[Ctr2] Control Method 2[Ftb2] Fixed Time Base 2[P

Strany 19 - Output 3 Process

Watlow Series SD • 24 • Chapter 3 Keys and Displays Programming Page Overview [Prog][PAgE]The Programming Page determines what parameters the user

Strany 20 - 12V (dc)

Watlow Series SD • 25 • Chapter 4 HomeNote: Some values will be rounded off to fit in the four-character display. Full values can be read with Modb

Strany 21 - Ethernet Gateway

Watlow Series SD • 26 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 22 - (profiling

Watlow Series SD • 27 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 23 - Home Page Overview

Watlow Series SD • 1 • Table of ContentsTCTable of ContentsChapter 1: Overview ...

Strany 24 - Operations Page Overview

Watlow Series SD • 28 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 25 - Setup Page Overview

Watlow Series SD • 29 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 26 - Factory Page Overview

Watlow Series SD • 30 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 27 - Read/Write

Watlow Series SD • 31 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 28

Watlow Series SD • 32 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 29

Watlow Series SD • 33 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 30

Watlow Series SD • 34 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 31

Watlow Series SD • 35 • Chapter 5 SetupDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parenthesis.)Default Modbus* (

Strany 32

Watlow Series SD • 36 • Chapter 6 Operations6These parameters can be selected to appear in the Operations Page. Select the parameters you want to

Strany 33

Watlow Series SD • 37 • Chapter 6 OperationsDisplay Parameter nameDescriptionSettings Range Default Modbus*(less 40,001 offset) Read/WriteAppears

Strany 34

Watlow Series SD • 2 • Chapter 1 OverviewThe Watlow Series SD family of PID, microproces-sor-based temperature controllers is available in 1/32, 1

Strany 35

Watlow Series SD • 38 • Chapter 6 OperationsDisplay Parameter nameDescriptionSettings Range Default Modbus*(less 40,001 offset) Read/WriteAppears

Strany 36

Watlow Series SD • 39 • Chapter 6 OperationsDisplay Parameter nameDescriptionSettings Range Default Modbus*(less 40,001 offset) Read/WriteAppears

Strany 37

Watlow Series SD • 40 • Chapter 7 Operations for TRU-TUNE+™7These parameters can be selected to appear in the Operations Page. Select the paramete

Strany 38 - Chapter 6:

Watlow Series SD • 41 • Chapter 7 Operations for TRU-TUNE+™Display Parameter nameDescriptionSettings Range Default Modbus*(less 40,001 offset) Rea

Strany 39

Watlow Series SD • 42 • Chapter 7 Operations for TRU-TUNE+™Display Parameter nameDescriptionSettings Range Default Modbus*(less 40,001 offset) Rea

Strany 40

Watlow Series SD • 43 • Chapter 8 ProgrammingChapter 8: Programming Page8The Programming Page allows you to select what parameters appear on the O

Strany 41

Watlow Series SD • 44 • Chapter 8 Programming Programming Page ExampleAn oven manufacturer wants users of their ovens to have easy access to the Se

Strany 42 - Chapter 7:

Watlow Series SD • 45 • Chapter 9 Programming for TRU-TUNE+™Chapter 9: Programming Page for TRU-TUNE+™ 9The Programming Page allows you to select

Strany 43

Watlow Series SD • 46 • Chapter 9 Programming for TRU-TUNE+™ Programming Page ExampleAn oven manufacturer wants users of their ovens to have easy

Strany 44

Watlow Series SD • 47 • Chapter 10 ProfilingThe Profiling Page allows you to enter your ramp and soak profile information. To go to the Profiling

Strany 45 - Chapter 8: Programming Page

Watlow Series SD • 3 • Chapter 1 OverviewFeatures and BenefitsINFOSENSE™ Technology• Improves sensor accuracy by a minimum of 50%.User Definable

Strany 46 - Programming Page Example

Watlow Series SD • 48 • Chapter 10 ProfilingDisplay Parameter nameDescriptionSet-tingsRange(Integer values for Mod-bus in parentheses.)Default Mod

Strany 47 - Chapter 9: Programming Page

Watlow Series SD • 49 • Chapter 10 ProfilingDisplay Parameter nameDescriptionSet-tingsRange(Integer values for Mod-bus in parentheses.)Default Mod

Strany 48

Watlow Series SD • 50 • Chapter 10 ProfilingDisplay Parameter nameDescriptionSet-tingsRange(Integer values for Mod-bus in parentheses.)Default Mod

Strany 49 - The Profiling Menu

Watlow Series SD • 51 • Chapter 10 Profiling Pre-Run Menu**The Pre-run prompts are only visible when in the Pre-Run mode. The Pre-Run mode is ent

Strany 50 - Set Point Step

Watlow Series SD • 52 • Chapter 10 Profiling Running a Profile To run a profile:1. You must start from the Home Page. Press the Infinity Key ˆ

Strany 51 - [SoaH] Soak Step

Watlow Series SD • 53 • Chapter 10 Profiling Soak StepA Soak step maintains the set point from the previous step for the time in hours, minutes a

Strany 52 - [~End] End Step

Watlow Series SD • 54 • Chapter 10 Profiling Example profileGwen, of Smith Manufacturing needs to perform a burn-in test of their product in an e

Strany 53 - Run Menu*

Watlow Series SD • 55 • Chapter 10 ProfilingCircle File Number: 1 2 3 4 Master Step Chart (Make a copy and write in your settings)Step

Strany 54 - Step Types

Watlow Series SD • 56 • Chapter 10 ProfilingSeries SD Profiling Modbus RegistersThis section contains information for creating, editing and runni

Strany 55 - Deviation Window

Watlow Series SD • 57 • Chapter 10 ProfilingDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parentheses.)Default Modb

Strany 56 - Example profile

Watlow Series SD • 4 • Table of ContentsWatlow Series SD • 4 • Chapter 2 Install and Wire Chapter 2: Install and Wire 1/16 DIN Series SD Contr

Strany 57

Watlow Series SD • 58 • Chapter 10 ProfilingSeries SD Profiling Modbus Register NumbersThis table contains the Modbus register numbers. The mumbe

Strany 58

Watlow Series SD • 59 • Chapter 11 Factory11Chapter 11: Factory PageTo go to the Factory Page, press both the Up ¿ and Down ¯ keys for six second

Strany 59

Watlow Series SD • 60 • Chapter 11 FactoryDisplay Parameter NameDescriptionSettings Range(Integer values for Modbus in parentheses.)Default Modbus

Strany 60

12Chapter 12: FeaturesSaving and Restoring User Settings . . . . . . . . . . . . . . . . . . . 62Saving and Restoring User Profiles . . . . . . . . .

Strany 61 - Chapter 11: Factory Page

Watlow Series SD • 62 • Chapter 12 FeaturesSaving and Restoring User SettingsRecording setup and operations parameter settings for future referen

Strany 62

Watlow Series SD • 63 • Chapter 12 Featureschange the selected parameter in the top display. If you do not want a parameter to appear for that loc

Strany 63 - Chapter 12: Features

Watlow Series SD • 64 • Chapter 12 Features Autotune Enable [`Aut]: The Autotune Enable pa-rameter appears in the Operations Page.The autotune fe

Strany 64 - Operations Page

Watlow Series SD • 65 • Chapter 12 FeaturesTimeTemperatureTemperature Reading from SensorActual Process TemperatureNegative Calibration Offset wil

Strany 65 - Temperature

Watlow Series SD • 66 • Chapter 12 FeaturesHigh Scale and Low ScaleWhen an analog input is selected as process voltage or process current input,

Strany 66 - Calibration Offset

Watlow Series SD • 67 • Chapter 12 Featuresmode and it is off while in the auto mode. For the profil-ing controller, the letter P appears in the l

Strany 67 - Access Lockout

Watlow Series SD • 5 • Table of ContentsWatlow Series SD • 5 • Chapter 2 Install and Wire 1/4 DIN Series SD Controller Dimensions ModelNumber

Strany 68 - Control Methods

Watlow Series SD • 68 • Chapter 12 Features Proportional plus Integral (PI) ControlThe droop caused by proportional control can be cor-rected by a

Strany 69

Watlow Series SD • 69 • Chapter 12 Features50% would result in an actual output power level of 50%. But if the PID calculated power output is 100%

Strany 70

Watlow Series SD • 70 • Chapter 12 Featuresing is done only at the zero cross of the ac line, which helps reduce electrical noise (RFI). Variable

Strany 71

Watlow Series SD • 71 • Chapter 12 Features Alarm HysteresisAn alarm state is triggered when the process value reaches the alarm high or alarm lo

Strany 72 - Alarm Set Points

Watlow Series SD • 72 • Chapter 12 FeaturesRTU protocol to read or write to registers in the control-ler. See the parameter tables for information

Strany 73 - Communications

Watlow Series SD • 73 • Chapter 12 Features7. Start communications with the controller.With the communications successfully verified, the software

Strany 74 - Setting Up a Modbus Network

Watlow Series SD • 74 • Chapter 1 OverviewWatlow Series SD • 74 • Chapter 12 Features Indication Probable Cause Corrective ActionNo power.Cont

Strany 75 - • 73 • Chapter 12 Features

Watlow Series SD • 75 • Chapter 1 OverviewWatlow Series SD • 75 • Chapter 12 Features Indication Probable Cause Corrective ActionGetting alar

Strany 76 - Troubleshooting

Watlow Series SD • 76 • Chapter 1 OverviewWatlow Series SD • 76 • Chapter 12 FeaturesError MessagesIndication Probable Cause Corrective Action

Strany 77

Watlow Series SD • 77 • Chapter 1 OverviewWatlow Series SD • 77 • AppendixAppendixA Specifications(2396)Controller• Microprocessor-based, user

Strany 78 - Error Messages

Watlow Series SD • 6 • Chapter 2 Install and Wire Installing and mounting requires access to theback of the panel.Removing the Screw Clamp Connec

Strany 79 - Specifications

Watlow Series SD • 78 • Chapter 1 OverviewWatlow Series SD • 78 • Appendix• Without contact suppression• Minimum load current: 10 mA rms• M

Strany 80

Watlow Series SD • 79 • Chapter 1 OverviewWatlow Series SD • 79 • AppendixS D____ ____- ____ ____ ____ ____ - ____A____ ____DIN Sizes 3, 6, 8

Strany 81 - ____ ____

Watlow Series SD • 80 • Chapter 1 OverviewWatlow Series SD • 80 • Appendix[A-M] 36, 40, 67[A1;hi] 25, 38, 41[A1hi] 75[A1;Lo] 25, 39, 42[A1

Strany 82 - Prompt Index

Watlow Series SD • 81 • Chapter 1 OverviewWatlow Series SD • 81 • AppendixAlarm 1 Silencing 32, 71Alarm 2 High 39, 42Alarm 2 Hysteresis 32,

Strany 83

Watlow Series SD • 82 • Chapter 1 OverviewWatlow Series SD • 82 • AppendixInfrared Data Communications (IDC) 73, 78inputs 64inputs and outpu

Strany 84

Watlow Series SD • 83 • Chapter 1 OverviewWatlow Series SD • 83 • Appendixexample 44, 46navigating to 62Proportional Band Cool 37, 41, 67Pr

Strany 85

Watlow Series SD • 84 • Chapter 1 OverviewWatlow Series SD • 84 • Appendix

Strany 86

Declaration of ConformitySeries SDWatlow Winona, Inc.1241 Bundy Blvd. Winona, MN 55987 USADeclares that the following product:Designation: Series SD

Strany 87 - Declaration of Conformity

How to Reach UsCorporate Headquarters in the U.S.:Watlow Electric Manufacturing Co.12001 Lackland RoadSt. Louis, Missouri, USA 63146Telephone: +1 (314

Strany 88 - How to Reach Us

Watlow Series SD • 7 • Chapter 2 Install and Wire Installing the 1/16 DIN Series SD ControllerGasketBezelPanelRetention CollarMounting BracketHoo