Temperature Control Output to MDR Coil Input
Please refer to the Field Coil Power Requirements when selecting the correct temperature control output.
Example: An HG35-1LD3-X000 requires 224mA to energize the coil and could be used with Watlow
temperature control output options B or K (i.e. 988A-XXBB-XXXX or 988A-XXKK-XXXX) models. The
best selection is the B output option because it includes an RC snubber across the output. If you select
the K option, it is recommended that you also purchase a Quencharc® snubber separately (Watlow part
number 0804-0147-0000). Place the snubber across the MDR coil terminals to protect the temperature
control solid state output. When placing the snubber across the coil of a 2 and 3 pole relay, you may have
to add some lead wire to the snubber. The MDR coil is an inductive load and the snubber will reduce the
flyback voltage produced by the MDR coil when it de-energizes. See below.
Note: Watlow temperature control solid state outputs will not drive VDC coils directly. Refer to the coil
current specifications above and any temperature control output specifications as required by the
application.
Quencharc
Snubber
(Purchase
Separately)
HG30-XAAX-0000
1 Pole 2 Pole 3 Pole
Voltage Current Power Current Power Current Power
24V~ (ac) NA NA 0.456A 10.9VA 0.510A 12.2VA
120V~ (ac) NA NA 0.121A 14.5VA 0.106A 12.7VA
208V~ (ac) NA NA 0.055A 11.4VA 0.055A 11.4VA
240V~ (ac) NA NA 0.063A 15.1VA 0.062A 14.9VA
24VÎ (dc) NA NA 0.240A 5.8W 0.250A 6.0W
HG30-XKDX-0000
HG35-XLDX-0000
HG50-XMDX-0000
HG60-XPDX-0000
1 Pole 2 Pole 3 Pole
Voltage Current Power Current Power Current Power
24V~ (ac) 0.235A 5.6VA 0.529A 12.7VA 1.270A 30.5VA
120V~ (ac) 0.057A 6.8VA 0.133A 16.0VA 0.224A 26.9VA
208V~ (ac) 0.030A 6.2VA 0.075A 15.6VA 0.111A 23.1VA
240V~ (ac) 0.035A 8.4VA 0.087A 20.9VA 0.128A 30.7VA
24VÎ (dc) 0.146A 3.5W 0.266A 6.4W 0.470A 11.3W
HG80-XABX-0000
HG1M-XACX-0000
HG2M-XADX-0000
1 Pole 2 Pole 3 Pole
Voltage Current Power Current Power Current Power
24V~ (ac) 0.930A 22.3VA 2.310A 55.4VA 5.060A 121.4VA
120V~ (ac) 0.195A 23.4VA 0.448A 53.8VA 0.968A 116.2VA
208V~ (ac) 0.097A 20.2VA 0.280A 58.2VA 0.482A 100.3VA
240V~ (ac) 0.112A 26.9VA 0.323A 77.5VA 0.563A 135.1VA
24VÎ (dc) 0.219A 5.2W 0.572A 13.7W 0.555A 13.3W
Field Coil Power Requirements
Watlow Series HG Mercury Displacement Relay Users Manual 4